Cross-Site Request Forgery (CSRF) in Siemens Ruggedcom Rox I (CVE-2017-2688)
Summary
Vulnerability in Siemens Ruggedcom Rox I (CVE-2017-2688). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow remote attackers to perform actions with the privileges of an authenticated user, provided the targeted user has an active session and is induced into clicking on a malicious link or into visiting a malicious website, aka CSRF.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2017-2688 has been found in Siemens Ruggedcom Rox I.
Successful exploitation can lead to full system takeover. CVSS score: 8.8/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Siemens Ruggedcom Rox I CVE-2017-2688" on the vendor's site.
CVE-2017-2688 (Siemens Ruggedcom Rox I) — CWE-352 / CVSS v3 8.8
Attack vector: remote (network-reachable) / unauthenticated
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
CSRF (CWE-352) exists in Siemens Ruggedcom Rox I.
Check the vendor advisory for the affected versions of Siemens Ruggedcom Rox I.
Severity: High (CVSS 8.8/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Siemens Ruggedcom Rox I を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- advisory securityfocus.com
- patch siemens.com
- web securitytracker.com
- web ics-cert.us-cert.gov