Categories
CVE-2017-9961 high CVSS 7.8

Vulnerability in Schneider Electric Pro Face Gp Pro Ex (CVE-2017-9961)

Summary

Vulnerability in Schneider Electric Pro Face Gp Pro Ex (CVE-2017-9961). Successful exploitation can lead to full system takeover.

Original description

The description as published by the source.

A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process.

Source: NIST National Vulnerability Database NVD

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2017-9961 has been found in Schneider Electric Pro Face Gp Pro Ex.
Successful exploitation can lead to full system takeover. CVSS score: 7.8/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Schneider Electric Pro Face Gp Pro Ex CVE-2017-9961" on the vendor's site.

CVE-2017-9961 (Schneider Electric Pro Face Gp Pro Ex) — CVSS v3 7.8
Attack vector: local / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (unclassified) exists in Schneider Electric Pro Face Gp Pro Ex.

📍 Affected scope

Check the vendor advisory for the affected versions of Schneider Electric Pro Face Gp Pro Ex.

🔥 Severity

Severity: High (CVSS 7.8/10). Successful exploitation can lead to full system takeover.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで Schneider Electric Pro Face Gp Pro Ex を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References

We use cookies for analytics and ad measurement. This setting applies to all Game co., Ltd. sites. Details