Vulnerability in Medtronic (CVE-2018-10626)
Summary
Vulnerability in Medtronic (CVE-2018-10626). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected product's update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.
Source: GitHub Security Advisories (Global) NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2018-10626 has been found in Medtronic.
Risk of unauthorized operations or information disclosure. CVSS score: 4.4/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Medtronic CVE-2018-10626" on the vendor's site.
CVE-2018-10626 (Medtronic) — CWE-345 / CVSS v3 4.4
Attack vector: adjacent-network / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-345) exists in Medtronic.
Check the vendor advisory for the affected versions of Medtronic.
Severity: Medium (CVSS 4.4/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Run grep -r 'Medtronic' . against your dependency files (package-lock.json, requirements.txt, go.sum) to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
grep -r 'Medtronic' . | grep -v node_modulesリポジトリと本番環境の依存ファイル (package-lock.json / requirements.txt / go.sum / Gemfile.lock 等) で
Medtronicを grep し、稼働しているサービス・バージョンを把握する。 -
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。