CVE-2022-4992 high CVSS 8.6

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1,...

Summary

Vulnerability reported (CVE-2022-4992). Risk of unauthorized operations or information disclosure.

Original description

The description as published by the source.

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower (with VG4.2 partially affected) contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service conditions. Attackers can compromise network communications to modify device settings such as alarm states or alarm limits, or overwhelm the system with excessive network traffic causing the Cockpit or M540 to reboot and lose network functionality.

Source: NIST National Vulnerability Database NVD GitHub Advisory

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2022-4992 has been found.
Risk of unauthorized operations or information disclosure. CVSS score: 8.6/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "CVE-2022-4992" on the vendor's site.

CVE-2022-4992 — CWE-345 / CVSS v3 8.6
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-345) has been reported.

📍 Affected scope

Check the vendor advisory for the affected versions.

🔥 Severity

Severity: High (CVSS 8.6/10). Risk of unauthorized operations or information disclosure.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで影響コンポーネントを特定する。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。