Use-After-Free in Siemens Solid Edge Se2025 (CVE-2026-50061)
Summary
Vulnerability in Siemens Solid Edge Se2025 (CVE-2026-50061). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.
Source: NIST National Vulnerability Database NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-50061 has been found in Siemens Solid Edge Se2025.
Successful exploitation can lead to full system takeover. CVSS score: 7.8/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Siemens Solid Edge Se2025 CVE-2026-50061" on the vendor's site.
CVE-2026-50061 (Siemens Solid Edge Se2025) — CWE-416 / CVSS v3 7.8
Attack vector: local / unauthenticated
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
Use-after-free (CWE-416) exists in Siemens Solid Edge Se2025.
Check the vendor advisory for the affected versions of Siemens Solid Edge Se2025.
Severity: High (CVSS 7.8/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Siemens Solid Edge Se2025 を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- patch productcert@siemens.com
- web nvd.nist.gov
- web github.com