Categories
CVE-2026-50110 critical CVSS 9.2

Vulnerability in Storage Concentrator (CVE-2026-50110)

Summary

Vulnerability in Storage Concentrator (CVE-2026-50110). Confidential information can be exposed externally.

Original description

The description as published by the source.

Storage Concentrator (SC & SCVM) contains hardcoded credentials for numerous internal services embedded within a configuration file. While the credentials are stored in an encoded format, the encoding can be reversed to plaintext. The exposed credentials span a broad range of internal services, including database accounts, licensing, replication services, and third-party integrations, meaning successful exploitation of this vulnerability could provide an attacker with unauthorized access to multiple interconnected systems.

Source: GitHub Security Advisories (Global) NVD GitHub Advisory

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-50110 has been found in Storage Concentrator.
Confidential information can be exposed externally. CVSS score: 9.2/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Storage Concentrator CVE-2026-50110" on the vendor's site.

CVE-2026-50110 (Storage Concentrator) — CWE-798 / CVSS v3 9.2
Attack vector: local / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-798) exists in Storage Concentrator.

📍 Affected scope

Check the vendor advisory for the affected versions of Storage Concentrator.

🔥 Severity

Severity: Critical (CVSS 9.2/10). Confidential information can be exposed externally.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで Storage Concentrator を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。