Categories
CVE-2026-5944 high CVSS 8.2

Vulnerability in Cisco Intersight Device Connector for Nutanix Prism Central (CVE-2026-5944)

Summary

Vulnerability in Cisco Intersight Device Connector for Nutanix Prism Central (CVE-2026-5944). Risk of unauthorized operations or information disclosure.

Original description

The description as published by the source.

An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central. The service exposes an API passthrough endpoint on TCP port 7373 that is accessible within the network scope of the deployment environment without authentication.

An unauthenticated attacker with network access can exploit this vulnerability by sending crafted requests to the exposed endpoint to enumerate cluster metadata, including virtual machine information and cluster configuration details. While the API primarily supports read-only operations, it also allows certain cluster maintenance workflows to be invoked.

Although this vulnerability does not allow persistent modification of system configurations or access to credentials or sensitive user data, successful exploitation may result in disruption of active workloads, leading to loss of service availability within the affected environment.

Source: NIST National Vulnerability Database NVD

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-5944 has been found in Cisco Intersight Device Connector for Nutanix Prism Central.
Risk of unauthorized operations or information disclosure. CVSS score: 8.2/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Cisco Intersight Device Connector for Nutanix Prism Central CVE-2026-5944" on the vendor's site.

CVE-2026-5944 (Cisco Intersight Device Connector for Nutanix Prism Central) — CWE-306 / CVSS v3 8.2
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-306) exists in Cisco Intersight Device Connector for Nutanix Prism Central.

📍 Affected scope

Check the vendor advisory for the affected versions of Cisco Intersight Device Connector for Nutanix Prism Central.

🔥 Severity

Severity: High (CVSS 8.2/10). Risk of unauthorized operations or information disclosure.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで Cisco Intersight Device Connector for Nutanix Prism Central を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References

We use cookies for analytics and ad measurement. This setting applies to all Game co., Ltd. sites. Details