Categories
CVE-2016-8355 critical CVSS 9.9

Vulnerability in Smiths-Medical CADD-Solis Medication Safety Software (CVE-2016-8355)

Summary

Vulnerability in Smiths-Medical CADD-Solis Medication Safety Software (CVE-2016-8355). Successful exploitation can lead to full system takeover.

Original description

The description as published by the source.

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates.

Source: NIST National Vulnerability Database NVD

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2016-8355 has been found in Smiths-Medical CADD-Solis Medication Safety Software.
Successful exploitation can lead to full system takeover. CVSS score: 9.9/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Smiths-Medical CADD-Solis Medication Safety Software CVE-2016-8355" on the vendor's site.

CVE-2016-8355 (Smiths-Medical CADD-Solis Medication Safety Software) — CWE-306 / CVSS v3 9.9
Attack vector: remote (network-reachable) / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-306) exists in Smiths-Medical CADD-Solis Medication Safety Software.

📍 Affected scope

Check the vendor advisory for the affected versions of Smiths-Medical CADD-Solis Medication Safety Software.

🔥 Severity

Severity: Critical (CVSS 9.9/10). Successful exploitation can lead to full system takeover.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで Smiths-Medical CADD-Solis Medication Safety Software を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References