Vulnerability in Smiths-Medical CADD-Solis Medication Safety Software (CVE-2016-8358)
Summary
Vulnerability in Smiths-Medical CADD-Solis Medication Safety Software (CVE-2016-8358). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2016-8358 has been found in Smiths-Medical CADD-Solis Medication Safety Software.
Successful exploitation can lead to full system takeover. CVSS score: 8.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Smiths-Medical CADD-Solis Medication Safety Software CVE-2016-8358" on the vendor's site.
CVE-2016-8358 (Smiths-Medical CADD-Solis Medication Safety Software) — CWE-346 / CVSS v3 8.5
Attack vector: remote (network-reachable) / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-346) exists in Smiths-Medical CADD-Solis Medication Safety Software.
Check the vendor advisory for the affected versions of Smiths-Medical CADD-Solis Medication Safety Software.
Severity: High (CVSS 8.5/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Smiths-Medical CADD-Solis Medication Safety Software を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- advisory securityfocus.com
- advisory ics-cert.us-cert.gov