Information Disclosure in SIMATIC S7-300 CPU family (CVE-2016-9159)
Summary
Vulnerability in SIMATIC S7-300 CPU family (CVE-2016-9159). Confidential information can be exposed externally.
Original description
The description as published by the source.
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2016-9159 has been found in SIMATIC S7-300 CPU family.
Confidential information can be exposed externally. CVSS score: 5.9/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "SIMATIC S7-300 CPU family CVE-2016-9159" on the vendor's site.
CVE-2016-9159 (SIMATIC S7-300 CPU family) — CWE-200 / CVSS v3 5.9
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
Information disclosure (CWE-200) exists in SIMATIC S7-300 CPU family.
Check the vendor advisory for the affected versions of SIMATIC S7-300 CPU family.
Severity: Medium (CVSS 5.9/10). Confidential information can be exposed externally.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで SIMATIC S7-300 CPU family を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- web securityfocus.com
- web securitytracker.com
- web cert-portal.siemens.com
- web ics-cert.us-cert.gov
- web siemens.com