Categories
CVE-2016-9360 medium CVSS 6.7

Vulnerability in General Electric (GE) Proficy HMI/SCADA iFIX (CVE-2016-9360)

Summary

Vulnerability in General Electric (GE) Proficy HMI/SCADA iFIX (CVE-2016-9360). Confidential information can be exposed externally.

Original description

The description as published by the source.

An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session.

Source: NIST National Vulnerability Database NVD

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2016-9360 has been found in General Electric (GE) Proficy HMI/SCADA iFIX.
Confidential information can be exposed externally. CVSS score: 6.7/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "General Electric (GE) Proficy HMI/SCADA iFIX CVE-2016-9360" on the vendor's site.

CVE-2016-9360 (General Electric (GE) Proficy HMI/SCADA iFIX) — CWE-522 / CVSS v3 6.7
Attack vector: local / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-522) exists in General Electric (GE) Proficy HMI/SCADA iFIX.

📍 Affected scope

Check the vendor advisory for the affected versions of General Electric (GE) Proficy HMI/SCADA iFIX.

🔥 Severity

Severity: Medium (CVSS 6.7/10). Confidential information can be exposed externally.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで General Electric (GE) Proficy HMI/SCADA iFIX を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References

We use cookies for analytics and ad measurement. This setting applies to all Game co., Ltd. sites. Details