Vulnerability in Juniper Junos (CVE-2017-10611)
Summary
Vulnerability in Juniper Junos (CVE-2017-10611). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
If extended statistics are enabled via 'set chassis extended-statistics', when executing any operation that fetches interface statistics, including but not limited to SNMP GET requests, the pfem process or the FPC may crash and restart. Repeated crashes of PFE processing can result in an extended denial of service condition. This issue only affects the following platforms: (1) EX2200, EX3300, XRE200 (2) MX Series routers with MPC7E/8E/9E PFEs installed, and only if 'extended-statistics' are enabled under the [edit chassis] configuration. Affected releases are Juniper Networks Junos OS 14.1 prior to 14.1R8-S5, 14.1R9 on MX Series; 14.1X53 prior to 14.1X53-D46, 14.1X53-D50 on EX2200, EX3300, XRE200; 14.2 prior to 14.2R7-S9, 14.2R8 on MX Series; 15.1 prior to 15.1F5-S8, 15.1F6-S8, 15.1R5-S3, 15.1R6 on MX Series; 16.1 prior to 16.1R4-S5, 16.1R5, 16.1R6 on MX Series; 16.1X65 prior to 16.1X65-D45 on EX2200, EX3300, XRE200; 16.2 prior to 16.2R2-S1, 16.2R3 on MX Series; 17.1 prior to 17.1R2-S2, 17.1R3 on MX Series; 17.2 prior to 17.2R1-S3, 17.2R2 on MX Series; 17.2X75 prior to 17.2X75-D50 on MX Series; 17.3 prior to 17.3R1-S1, 17.3R2 on MX Series. No other Juniper Networks products or platforms are affected by this issue.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2017-10611 has been found in Juniper Junos.
Risk of unauthorized operations or information disclosure. CVSS score: 6.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Juniper Junos CVE-2017-10611" on the vendor's site.
CVE-2017-10611 (Juniper Junos) — CVSS v3 6.5
Attack vector: remote (network-reachable) / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (unclassified) exists in Juniper Junos.
Check the vendor advisory for the affected versions of Juniper Junos.
Severity: Medium (CVSS 6.5/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Run grep -r 'Junos' . against your dependency files (package-lock.json, requirements.txt, go.sum) to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
grep -r 'Junos' . | grep -v node_modulesリポジトリと本番環境の依存ファイル (package-lock.json / requirements.txt / go.sum / Gemfile.lock 等) で
Junosを grep し、稼働しているサービス・バージョンを把握する。 -
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- patch kb.juniper.net