Vulnerability in Schneider Electric Modicon M251 Firmware (CVE-2017-6026)
Summary
Vulnerability in Schneider Electric Modicon M251 Firmware (CVE-2017-6026). Confidential information can be exposed externally.
Original description
The description as published by the source.
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2017-6026 has been found in Schneider Electric Modicon M251 Firmware.
Confidential information can be exposed externally. CVSS score: 9.1/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Schneider Electric Modicon M251 Firmware CVE-2017-6026" on the vendor's site.
CVE-2017-6026 (Schneider Electric Modicon M251 Firmware) — CWE-330 / CVSS v3 9.1
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-330) exists in Schneider Electric Modicon M251 Firmware.
Check the vendor advisory for the affected versions of Schneider Electric Modicon M251 Firmware.
Severity: Critical (CVSS 9.1/10). Confidential information can be exposed externally.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Schneider Electric Modicon M251 Firmware を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- advisory securityfocus.com
- advisory ics-cert.us-cert.gov
- exploit exploit-db.com