Vulnerability in Cisco Firepower Threat Defense (CVE-2017-6632)
Summary
Vulnerability in Cisco Firepower Threat Defense (CVE-2017-6632). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
A vulnerability in the logging configuration of Secure Sockets Layer (SSL) policies for Cisco FirePOWER System Software 5.3.0 through 6.2.2 could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition due to high consumption of system resources. The vulnerability is due to the logging of certain TCP packets by the affected software. An attacker could exploit this vulnerability by sending a flood of crafted TCP packets to an affected device. A successful exploit could allow the attacker to cause a DoS condition. The success of an exploit is dependent on how an administrator has configured logging for SSL policies for a device. This vulnerability affects Cisco FirePOWER System Software that is configured to log connections by using SSL policy default actions. Cisco Bug IDs: CSCvd07072.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2017-6632 has been found in Cisco Firepower Threat Defense.
Risk of unauthorized operations or information disclosure. CVSS score: 7.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Cisco Firepower Threat Defense CVE-2017-6632" on the vendor's site.
CVE-2017-6632 (Cisco Firepower Threat Defense) — CWE-399 / CVSS v3 7.5
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-399) exists in Cisco Firepower Threat Defense.
Check the vendor advisory for the affected versions of Cisco Firepower Threat Defense.
Severity: High (CVSS 7.5/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Cisco Firepower Threat Defense を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- advisory securityfocus.com
- patch tools.cisco.com