Vulnerability in Multilin Sr 750 Feeder Protection Relay Firmware (CVE-2017-7905)
Summary
Vulnerability in Multilin Sr 750 Feeder Protection Relay Firmware (CVE-2017-7905). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2017-7905 has been found in Multilin Sr 750 Feeder Protection Relay Firmware.
Successful exploitation can lead to full system takeover. CVSS score: 9.8/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Multilin Sr 750 Feeder Protection Relay Firmware CVE-2017-7905" on the vendor's site.
CVE-2017-7905 (Multilin Sr 750 Feeder Protection Relay Firmware) — CWE-261 / CVSS v3 9.8
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-261) exists in Multilin Sr 750 Feeder Protection Relay Firmware.
Check the vendor advisory for the affected versions of Multilin Sr 750 Feeder Protection Relay Firmware.
Severity: Critical (CVSS 9.8/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Multilin Sr 750 Feeder Protection Relay Firmware を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- advisory securityfocus.com
- patch ics-cert.us-cert.gov