Vulnerability in Rockwellautomation (CVE-2017-7924)
Summary
Vulnerability in Rockwellautomation (CVE-2017-7924). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. A remote, unauthenticated attacker could send a single, specially crafted Programmable Controller Communication Commands (PCCC) packet to the controller that could potentially cause the controller to enter a DoS condition.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2017-7924 has been found in Rockwellautomation.
Risk of unauthorized operations or information disclosure. CVSS score: 7.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Rockwellautomation CVE-2017-7924" on the vendor's site.
CVE-2017-7924 (Rockwellautomation) — CWE-20 / CVSS v3 7.5
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-20) exists in Rockwellautomation.
Check the vendor advisory for the affected versions of Rockwellautomation.
Severity: High (CVSS 7.5/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Run grep -r 'Rockwellautomation' . against your dependency files (package-lock.json, requirements.txt, go.sum) to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
grep -r 'Rockwellautomation' . | grep -v node_modulesリポジトリと本番環境の依存ファイル (package-lock.json / requirements.txt / go.sum / Gemfile.lock 等) で
Rockwellautomationを grep し、稼働しているサービス・バージョンを把握する。 -
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- advisory securityfocus.com
- advisory ics-cert.us-cert.gov