Buffer Overflow in Schneider Electric Vampset (CVE-2017-7967)
Summary
Vulnerability in Schneider Electric Vampset (CVE-2017-7967). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2017-7967 has been found in Schneider Electric Vampset.
Risk of unauthorized operations or information disclosure. CVSS score: 5.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Schneider Electric Vampset CVE-2017-7967" on the vendor's site.
CVE-2017-7967 (Schneider Electric Vampset) — CWE-119 / CVSS v3 5.5
Attack vector: local / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-119) exists in Schneider Electric Vampset.
Check the vendor advisory for the affected versions of Schneider Electric Vampset.
Severity: Medium (CVSS 5.5/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Run grep -r 'Vampset' . against your dependency files (package-lock.json, requirements.txt, go.sum) to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
grep -r 'Vampset' . | grep -v node_modulesリポジトリと本番環境の依存ファイル (package-lock.json / requirements.txt / go.sum / Gemfile.lock 等) で
Vampsetを grep し、稼働しているサービス・バージョンを把握する。 -
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- patch schneider-electric.com
- web securityfocus.com