Vulnerability in Solarwinds Network Performance Monitor (CVE-2017-9538)
Summary
Vulnerability in Solarwinds Network Performance Monitor (CVE-2017-9538). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
The 'Upload logo from external path' function of SolarWinds Network Performance Monitor version 12.0.15300.90 allows remote attackers to cause a denial of service (permanent display of a "Cannot exit above the top directory" error message throughout the entire web application) via a ".." in the path field. In other words, the denial of service is caused by an incorrect implementation of a directory-traversal protection mechanism.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2017-9538 has been found in Solarwinds Network Performance Monitor.
Risk of unauthorized operations or information disclosure. CVSS score: 4.9/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Solarwinds Network Performance Monitor CVE-2017-9538" on the vendor's site.
CVE-2017-9538 (Solarwinds Network Performance Monitor) — CWE-20 / CVSS v3 4.9
Attack vector: remote (network-reachable) / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-20) exists in Solarwinds Network Performance Monitor.
Check the vendor advisory for the affected versions of Solarwinds Network Performance Monitor.
Severity: Medium (CVSS 4.9/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Solarwinds Network Performance Monitor を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- advisory securityfocus.com
- web securityfocus.com