Categories
CVE-2020-15798 critical CVSS 9.8

Vulnerability in SIMATIC HMI Comfort Panels (CVE-2020-15798)

Summary

Vulnerability in SIMATIC HMI Comfort Panels (CVE-2020-15798). Successful exploitation can lead to full system takeover.

Original description

The description as published by the source.

A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)

Source: NIST National Vulnerability Database NVD

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2020-15798 has been found in SIMATIC HMI Comfort Panels.
Successful exploitation can lead to full system takeover. CVSS score: 9.8/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "SIMATIC HMI Comfort Panels CVE-2020-15798" on the vendor's site.

CVE-2020-15798 (SIMATIC HMI Comfort Panels) — CWE-306 / CVSS v3 9.8
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-306) exists in SIMATIC HMI Comfort Panels.

📍 Affected scope

Check the vendor advisory for the affected versions of SIMATIC HMI Comfort Panels.

🔥 Severity

Severity: Critical (CVSS 9.8/10). Successful exploitation can lead to full system takeover.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで SIMATIC HMI Comfort Panels を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References

We use cookies for analytics and ad measurement. This setting applies to all Game co., Ltd. sites. Details