Vulnerability in Schneider Electric Ecostruxure Machine Expert (CVE-2020-7488)
Summary
Vulnerability in Schneider Electric Ecostruxure Machine Expert (CVE-2020-7488). Confidential information can be exposed externally.
Original description
The description as published by the source.
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.
Source: GitHub Security Advisories (Global) NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2020-7488 has been found in Schneider Electric Ecostruxure Machine Expert.
Confidential information can be exposed externally. CVSS score: 7.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Schneider Electric Ecostruxure Machine Expert CVE-2020-7488" on the vendor's site.
CVE-2020-7488 (Schneider Electric Ecostruxure Machine Expert) — CWE-319 / CVSS v3 7.5
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-319) exists in Schneider Electric Ecostruxure Machine Expert.
Check the vendor advisory for the affected versions of Schneider Electric Ecostruxure Machine Expert.
Severity: High (CVSS 7.5/10). Confidential information can be exposed externally.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Schneider Electric Ecostruxure Machine Expert を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- patch se.com
- web nvd.nist.gov