CVE-2021-22779 critical CVSS 9.1

Vulnerability in Schneider Electric Ecostruxure Control Expert (CVE-2021-22779)

Summary

Vulnerability in Schneider Electric Ecostruxure Control Expert (CVE-2021-22779). Confidential information can be exposed externally.

Original description

The description as published by the source.

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.

Source: GitHub Security Advisories (Global) NVD GitHub Advisory

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2021-22779 has been found in Schneider Electric Ecostruxure Control Expert.
Confidential information can be exposed externally. CVSS score: 9.1/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Schneider Electric Ecostruxure Control Expert CVE-2021-22779" on the vendor's site.

CVE-2021-22779 (Schneider Electric Ecostruxure Control Expert) — CWE-290 / CVSS v3 9.1
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-290) exists in Schneider Electric Ecostruxure Control Expert.

📍 Affected scope

Check the vendor advisory for the affected versions of Schneider Electric Ecostruxure Control Expert.

🔥 Severity

Severity: Critical (CVSS 9.1/10). Confidential information can be exposed externally.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで Schneider Electric Ecostruxure Control Expert を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。