Vulnerability in Schneider Electric Ecostruxure Control Expert (CVE-2021-22779)
Summary
Vulnerability in Schneider Electric Ecostruxure Control Expert (CVE-2021-22779). Confidential information can be exposed externally.
Original description
The description as published by the source.
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.
Source: GitHub Security Advisories (Global) NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2021-22779 has been found in Schneider Electric Ecostruxure Control Expert.
Confidential information can be exposed externally. CVSS score: 9.1/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Schneider Electric Ecostruxure Control Expert CVE-2021-22779" on the vendor's site.
CVE-2021-22779 (Schneider Electric Ecostruxure Control Expert) — CWE-290 / CVSS v3 9.1
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-290) exists in Schneider Electric Ecostruxure Control Expert.
Check the vendor advisory for the affected versions of Schneider Electric Ecostruxure Control Expert.
Severity: Critical (CVSS 9.1/10). Confidential information can be exposed externally.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Schneider Electric Ecostruxure Control Expert を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- patch download.schneider-electric.com
- web nvd.nist.gov
- web github.com