A vulnerability, which was classified as problematic, has been found in dbartholomae lambda-middleware frameguard up to…
Summary
Vulnerability reported (CVE-2021-4437). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
A vulnerability, which was classified as problematic, has been found in dbartholomae lambda-middleware frameguard up to 1.0.4. Affected by this issue is some unknown functionality of the file packages/json-deserializer/src/JsonDeserializer.ts of the component JSON Mime-Type Handler. The manipulation leads to inefficient regular expression complexity. Upgrading to version 1.1.0 is able to address this issue. The patch is identified as f689404d830cbc1edd6a1018d3334ff5f44dc6a6. It is recommended to upgrade the affected component. VDB-253406 is the identifier assigned to this vulnerability.
Source: OSV.dev (Open Source Vulnerabilities) NVD GitHub Advisory OSV
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2021-4437 has been found.
Risk of unauthorized operations or information disclosure.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "CVE-2021-4437" on the vendor's site.
CVE-2021-4437
Attack vector: adjacent-network / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (unclassified) has been reported.
Check the vendor advisory for the affected versions.
Severity: ?. Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで影響コンポーネントを特定する。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- advisory github.com
- advisory vuldb.com
- patch github.com
- patch github.com
- report vuldb.com