Vulnerability in Hirschmann Industrial HiVision (CVE-2022-4987)
Summary
Vulnerability in Hirschmann Industrial HiVision (CVE-2022-4987). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
Hirschmann Industrial HiVision version 08.1.03 prior to 08.1.04 and 08.2.00 contains a vulnerability in the execution of user-configured external applications that allows a local attacker to execute arbitrary binaries. Due to insufficient path sanitization, an attacker can place a malicious binary in the execution path of a configured external application, causing it to be executed instead of the intended application. This can result in execution with elevated privileges depending on the context of the external application.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2022-4987 has been found in Hirschmann Industrial HiVision.
Successful exploitation can lead to full system takeover. CVSS score: 7.3/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Hirschmann Industrial HiVision CVE-2022-4987" on the vendor's site.
CVE-2022-4987 (Hirschmann Industrial HiVision) — CWE-426 / CVSS v3 7.3
Attack vector: local
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-426) exists in Hirschmann Industrial HiVision.
Check the vendor advisory for the affected versions of Hirschmann Industrial HiVision.
Severity: High (CVSS 7.3/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Hirschmann Industrial HiVision を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。