Vulnerability in Trusted Firmware-M (CVE-2023-40271)
Summary
Vulnerability in Trusted Firmware-M (CVE-2023-40271). Data can be tampered with by attackers.
Original description
The description as published by the source.
In Trusted Firmware-M through TF-Mv1.8.0, for platforms that integrate the CryptoCell accelerator, when the CryptoCell PSA Driver software Interface is selected, and the Authenticated Encryption with Associated Data Chacha20-Poly1305 algorithm is used, with the single-part verification function (defined during the build-time configuration phase) implemented with a dedicated function (i.e., not relying on usage of multipart functions), the buffer comparison during the verification of the authentication tag does not happen on the full 16 bytes but just on the first 4 bytes, thus leading to the possibility that unauthenticated payloads might be identified as authentic. This affects TF-Mv1.6.0, TF-Mv1.6.1, TF-Mv1.7.0, and TF-Mv1.8.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2023-40271 has been found in Trusted Firmware-M.
Data can be tampered with by attackers. CVSS score: 7.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Trusted Firmware-M CVE-2023-40271" on the vendor's site.
CVE-2023-40271 (Trusted Firmware-M) — CWE-697 / CVSS v3 7.5
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-697) exists in Trusted Firmware-M.
Check the vendor advisory for the affected versions of Trusted Firmware-M.
Severity: High (CVSS 7.5/10). Data can be tampered with by attackers.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Trusted Firmware-M を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。