Vulnerability in D-Link DI-7100G C1 (CVE-2025-11335)
Summary
Vulnerability in D-Link DI-7100G C1 (CVE-2025-11335). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
A weakness has been identified in D-Link DI-7100G C1 up to 20250928. Affected by this vulnerability is the function sub_46409C of the file /msp_info.htm?flag=qos of the component jhttpd. This manipulation of the argument iface causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2025-11335 has been found in D-Link DI-7100G C1.
Risk of unauthorized operations or information disclosure. CVSS score: 4.7/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "D-Link DI-7100G C1 CVE-2025-11335" on the vendor's site.
CVE-2025-11335 (D-Link DI-7100G C1) — CWE-74 / CVSS v3 4.7
Attack vector: remote (network-reachable) / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-74) exists in D-Link DI-7100G C1.
Check the vendor advisory for the affected versions of D-Link DI-7100G C1.
Severity: Medium (CVSS 4.7/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで D-Link DI-7100G C1 を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。