Vulnerability in Circutor SGE-PLC1000/SGE-PLC50 (CVE-2025-11784)
Summary
Vulnerability in Circutor SGE-PLC1000/SGE-PLC50 (CVE-2025-11784). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2025-11784 has been found in Circutor SGE-PLC1000/SGE-PLC50.
Successful exploitation can lead to full system takeover. CVSS score: 9.8/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Circutor SGE-PLC1000/SGE-PLC50 CVE-2025-11784" on the vendor's site.
CVE-2025-11784 (Circutor SGE-PLC1000/SGE-PLC50) — CWE-121 / CVSS v3 9.8
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-121) exists in Circutor SGE-PLC1000/SGE-PLC50.
Check the vendor advisory for the affected versions of Circutor SGE-PLC1000/SGE-PLC50.
Severity: Critical (CVSS 9.8/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Circutor SGE-PLC1000/SGE-PLC50 を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- advisory cve-coordination@incibe.es