Categories
CVE-2025-14038 high CVSS 7.0

Vulnerability in EDB Hybrid Manager (CVE-2025-14038)

Summary

Vulnerability in EDB Hybrid Manager (CVE-2025-14038). Risk of unauthorized operations or information disclosure.

Original description

The description as published by the source.

EDB Hybrid Manager contains a flaw that allows an unauthenticated attacker to directly access certain gRPC endpoints. This could allow an attacker to read potentially sensitive data or possibly cause a denial-of-service by writing malformed data to certain gRPC endpoints. This flaw has been remediated in EDB Hybrid Manager 1.3.3, and customers should consider upgrading to 1.3.3 as soon as possible.
The flaw is due to a misconfiguration in the Istio Gateway, which manages authentication and authorization for the affected endpoints. The security policy relies on an explicit definition of required permissions in the Istio Gateway configuration, and the affected endpoints were not defined in the configuration. This allowed requests to bypass both authentication and authorization within a Hybrid Manager service.
All versions of Hybrid Manager - LTS should be upgraded to 1.3.3, and all versions of Hybrid Manager - Innovation should be upgraded to 2025.12.

Source: NIST National Vulnerability Database NVD

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2025-14038 has been found in EDB Hybrid Manager.
Risk of unauthorized operations or information disclosure. CVSS score: 7.0/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "EDB Hybrid Manager CVE-2025-14038" on the vendor's site.

CVE-2025-14038 (EDB Hybrid Manager) — CWE-306 / CVSS v3 7.0
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-306) exists in EDB Hybrid Manager.

📍 Affected scope

Check the vendor advisory for the affected versions of EDB Hybrid Manager.

🔥 Severity

Severity: High (CVSS 7.0/10). Risk of unauthorized operations or information disclosure.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで EDB Hybrid Manager を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References