Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter…
Summary
Vulnerability reported (CVE-2025-36463). Successful exploitation can lead to full system takeover. Exploitable via WinBioControlUnit.
Original description
The description as published by the source.
Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. This vulnerability is triggered when submitting a WinBioControlUnit call to the StorageAdapter with the ControlCode 4 (WBIO_USH_ADD_RECORD) and with an invalid SendBufferSize.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2025-36463 has been found.
Attackers can target a specific entry point like WinBioControlUnit over the network to misuse the product.
Successful exploitation can lead to full system takeover. CVSS score: 7.3/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "CVE-2025-36463" on the vendor's site.
CVE-2025-36463 — CWE-805 / CVSS v3 7.3
Attack vector: local
Attack surface: WinBioControlUnit / WBIO_USH_ADD_RECORD / SendBufferSize
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-805) has been reported. Attackers reach the vulnerable code path via WinBioControlUnit.
Check the vendor advisory for the affected versions. Attack surface: WinBioControlUnit / WBIO_USH_ADD_RECORD / SendBufferSize.
Severity: High (CVSS 7.3/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで影響コンポーネントを特定する。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。