XXE (XML External Entity) in Dell Unisphere for PowerMax (CVE-2025-36589)
Summary
Vulnerability in Dell Unisphere for PowerMax (CVE-2025-36589). Confidential information can be exposed externally.
Original description
The description as published by the source.
Dell Unisphere for PowerMax, version(s) 9.2.4.x, contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access to data and resources outside of the intended sphere of control.
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2025-36589 has been found in Dell Unisphere for PowerMax.
Confidential information can be exposed externally. CVSS score: 7.6/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Dell Unisphere for PowerMax CVE-2025-36589" on the vendor's site.
CVE-2025-36589 (Dell Unisphere for PowerMax) — CWE-611 / CVSS v3 7.6
Attack vector: remote (network-reachable) / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-611) exists in Dell Unisphere for PowerMax.
Check the vendor advisory for the affected versions of Dell Unisphere for PowerMax.
Severity: High (CVSS 7.6/10). Confidential information can be exposed externally.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Dell Unisphere for PowerMax を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- patch security_alert@emc.com