Categories
CVE-2025-3756 medium CVSS 6.5

A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions…

Summary

Vulnerability reported (CVE-2025-3756). Risk of unauthorized operations or information disclosure.

Original description

The description as published by the source.

A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation. 

The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.

   

This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.

Source: NIST National Vulnerability Database NVD

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2025-3756 has been found.
Risk of unauthorized operations or information disclosure. CVSS score: 6.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "CVE-2025-3756" on the vendor's site.

CVE-2025-3756 — CWE-1284 / CVSS v3 6.5
Attack vector: adjacent-network / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-1284) has been reported.

📍 Affected scope

Check the vendor advisory for the affected versions.

🔥 Severity

Severity: Medium (CVSS 6.5/10). Risk of unauthorized operations or information disclosure.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで影響コンポーネントを特定する。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References

We use cookies for analytics and ad measurement. This setting applies to all Game co., Ltd. sites. Details