Vulnerability in OpenPLC_V3
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2025-54811 has been found in OpenPLC_V3.
Risk of unauthorized operations or information disclosure. CVSS score: 7.1/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "OpenPLC_V3 CVE-2025-54811" on the vendor's site.
CVE-2025-54811 (OpenPLC_V3) — CWE-758 / CVSS v3 7.1
Attack vector: local / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-758) exists in OpenPLC_V3.
Check the vendor advisory for the affected versions of OpenPLC_V3.
Severity: High (CVSS 7.1/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Run grep -r 'OpenPLC_V3' . against your dependency files (package-lock.json, requirements.txt, go.sum) to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1
Identify exposureidentify
grep -r 'OpenPLC_V3' . | grep -v node_modulesリポジトリと本番環境の依存ファイル (package-lock.json / requirements.txt / go.sum / Gemfile.lock 等) で
OpenPLC_V3を grep し、稼働しているサービス・バージョンを把握する。 -
2
Post-deployment verificationverify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
Original description The description as published by the source.
OpenPLC_V3 has a vulnerability in the enipThread function that occurs due to the lack of a return value. This leads to a crash when the server loop ends and execution hits an illegal ud2 instruction. This issue can be triggered remotely without authentication by starting the same server multiple times or if the server exits unexpectedly. The vulnerability allows an attacker to cause a Denial of Service (DoS) against the PLC runtime, stopping any PC started remotely without authentication. This results in the PLC process crashing and halting all automation or control logic managed by OpenPLC.
Source: NIST National Vulnerability Database NVD