Information Disclosure in Froxlor (CVE-2026-100708)
Summary
Vulnerability in Froxlor (CVE-2026-100708). Confidential information can be exposed externally.
Original description
The description as published by the source.
Froxlor before 2.3.13 returns the ssl_key_file column — which stores the raw PEM TLS private-key content — verbatim in the JSON responses of the Certificates.get and Certificates.listing API commands, because the results of the underlying domain_ssl_settings queries are passed through ApiCommand::response() without any field stripping or allowlist. A low-privileged authenticated customer API caller can retrieve the private keys of their own domains' certificates, including Let's Encrypt keys that Froxlor generates server-side and stores root-only (0600) and to which the customer otherwise has no filesystem access; reseller and customers_see_all admin accounts can dump the private keys of other principals through the same sink. Disclosed keys enable domain impersonation, passive decryption of captured TLS traffic, and active machine-in-the-middle attacks.
Source: NIST National Vulnerability Database NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-100708 has been found in Froxlor.
Confidential information can be exposed externally. CVSS score: 7.1/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Froxlor CVE-2026-100708" on the vendor's site.
CVE-2026-100708 (Froxlor) — CWE-200 / CVSS v3 7.1
Attack vector: remote (network-reachable) / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
Information disclosure (CWE-200) exists in Froxlor.
Check the vendor advisory for the affected versions of Froxlor.
Severity: High (CVSS 7.1/10). Confidential information can be exposed externally.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Run grep -r 'Froxlor' . against your dependency files (package-lock.json, requirements.txt, go.sum) to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
grep -r 'Froxlor' . | grep -v node_modulesリポジトリと本番環境の依存ファイル (package-lock.json / requirements.txt / go.sum / Gemfile.lock 等) で
Froxlorを grep し、稼働しているサービス・バージョンを把握する。 -
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- web github.com
- web vulncheck.com
- web nvd.nist.gov
- web github.com