Buffer Overflow in Tenda AC9 (CVE-2026-104611)
Summary
Vulnerability in Tenda AC9 (CVE-2026-104611). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
A vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
Source: NIST National Vulnerability Database NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-104611 has been found in Tenda AC9.
Successful exploitation can lead to full system takeover. CVSS score: 9.1/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Tenda AC9 CVE-2026-104611" on the vendor's site.
CVE-2026-104611 (Tenda AC9) — CWE-119 / CVSS v3 9.1
Attack vector: remote (network-reachable) / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-119) exists in Tenda AC9.
Check the vendor advisory for the affected versions of Tenda AC9.
Severity: Critical (CVSS 9.1/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Tenda AC9 を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- web github.com
- web vuldb.com
- web vuldb.com
- web vuldb.com
- web vuldb.com
- web cna@vuldb.com
- web nvd.nist.gov
- web tenda.com.cn
- web github.com