Categories
CVE-2026-107819 medium CVSS 5.9

Vulnerability in MariaDB Connector/C (CVE-2026-107819)

Summary

Vulnerability in MariaDB Connector/C (CVE-2026-107819). Confidential information can be exposed externally.

Original description

The description as published by the source.

MariaDB Connector/C is a C and C++ client library for connecting applications to MariaDB and MySQL databases. From 3.4.1 until 3.4.10, the MariaDB Connector/C libmariadb Zero-Configuration SSL authentication-switch logic checked certificate trust failure but did not reject a TLS hostname verification mismatch before selecting a non-hashing authentication plugin. An active man-in-the-middle attacker with a valid certificate for another hostname could request mysql_clear_password and obtain the database password inside the attacker-controlled TLS connection. Other MariaDB connectors are not affected. This issue is fixed in version 3.4.10.

Source: NIST National Vulnerability Database NVD

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-107819 has been found in MariaDB Connector/C.
Confidential information can be exposed externally. CVSS score: 5.9/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "MariaDB Connector/C CVE-2026-107819" on the vendor's site.

CVE-2026-107819 (MariaDB Connector/C) — CWE-297 / CVSS v3 5.9
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-297) exists in MariaDB Connector/C.

📍 Affected scope

Check the vendor advisory for the affected versions of MariaDB Connector/C.

🔥 Severity

Severity: Medium (CVSS 5.9/10). Confidential information can be exposed externally.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで MariaDB Connector/C を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。