Vulnerability in Edgeless Systems Contrast (CVE-2026-109358)
Summary
Vulnerability in Edgeless Systems Contrast (CVE-2026-109358). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
Edgeless Systems Contrast 1.8.0 before 1.24.1 contains an incorrect permissions vulnerability where the node installer writes the containerd config world-writable (0666). Local unprivileged users on the node can modify the containerd config, for example overwriting the runc location, to escalate privileges.
Source: NIST National Vulnerability Database NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-109358 has been found in Edgeless Systems Contrast.
Successful exploitation can lead to full system takeover. CVSS score: 7.8/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Edgeless Systems Contrast CVE-2026-109358" on the vendor's site.
CVE-2026-109358 (Edgeless Systems Contrast) — CWE-732 / CVSS v3 7.8
Attack vector: local / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-732) exists in Edgeless Systems Contrast.
Check the vendor advisory for the affected versions of Edgeless Systems Contrast.
Severity: High (CVSS 7.8/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Edgeless Systems Contrast を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- web disclosure@vulncheck.com
- web disclosure@vulncheck.com
- web nvd.nist.gov