Lantronix XPress-DR and XPress-DR-I (CoBos-family) firmware through 8.1.0.0 contains a missing...
Summary
Vulnerability reported (CVE-2026-109439). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
Lantronix XPress-DR and XPress-DR-I (CoBos-family) firmware through 8.1.0.0 contains a missing authentication vulnerability that allows remote attackers to read and persistently overwrite device configuration by sending crafted frames to the unauthenticated UDP configuration protocol on port 30718. Attackers can send a type 0xF8 query to read live configuration data and a type 0xFD frame with exactly 0x78 body bytes to rewrite the device IP address and serial-channel forwarding records, causing changes to commit to EEPROM and persist across reboots. The XPress-DR product series reached end-of-life/end-of-support in February 2025.
Source: GitHub Security Advisories (Global) NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-109439 has been found.
Successful exploitation can lead to full system takeover. CVSS score: 9.8/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "CVE-2026-109439" on the vendor's site.
CVE-2026-109439 — CWE-306 / CVSS v3 9.8
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-306) has been reported.
Check the vendor advisory for the affected versions.
Severity: Critical (CVSS 9.8/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで影響コンポーネントを特定する。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- web nvd.nist.gov
- web disclosure@vulncheck.com
- web disclosure@vulncheck.com
- web github.com