GV-I/O Box 4E is a smart embedded device with 4 input and 4 relays output that can be controlled...
Summary
Vulnerability reported (CVE-2026-12848). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
GV-I/O Box 4E is a smart embedded device with 4 input and 4 relays output that can be controlled over Ethernet and RS-485.
DVRSearch is a service running by default on the IOBox listening for UDP messages on port 10001. Any user on the network can send messages to this service and interact with it.
Upon receiving a UDP message, the server reads at most 1460 bytes into a local buffer and a pointer to the buffer is stored in a global variable:
DNS field stack overflow
The following code is vulnerable to a stack overflow that is attacker-controlled:
v8 = strlen(g_network_config->dns_addr);
memcpy(&reply_buf[248], g_network_config->dns_addr, v8);
Source: NIST National Vulnerability Database NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-12848 has been found.
Successful exploitation can lead to full system takeover. CVSS score: 10.0/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "CVE-2026-12848" on the vendor's site.
CVE-2026-12848 — CWE-121 / CVSS v3 10.0
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-121) has been reported.
Check the vendor advisory for the affected versions.
Severity: Critical (CVSS 10.0/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで影響コンポーネントを特定する。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- web talosintelligence.com
- web geovision.com.tw
- web nvd.nist.gov
- web github.com