Categories
CVE-2026-13380 high CVSS 7.5

Vulnerability in VSee Clinic (CVE-2026-13380)

Summary

Vulnerability in VSee Clinic (CVE-2026-13380). Confidential information can be exposed externally.

Original description

The description as published by the source.

VSee Clinic 7.1.26 and VSee Clinic API 1.3.0 exposes cleartext SFTP credentials in the HTTP responses of three unauthenticated endpoints. The credentials are present in these responses only when SFTP connections have been configured within the application. No authentication is required to retrieve these credentials. An unauthenticated remote attacker who observes any of these HTTP responses on an instance where SFTP is configured can obtain the credentials and use them to access the associated SFTP server.

Source: NIST National Vulnerability Database NVD GitHub Advisory

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-13380 has been found in VSee Clinic.
Confidential information can be exposed externally. CVSS score: 7.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "VSee Clinic CVE-2026-13380" on the vendor's site.

CVE-2026-13380 (VSee Clinic) — CWE-201 / CVSS v3 7.5
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-201) exists in VSee Clinic.

📍 Affected scope

Check the vendor advisory for the affected versions of VSee Clinic.

🔥 Severity

Severity: High (CVSS 7.5/10). Confidential information can be exposed externally.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで VSee Clinic を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References

We use cookies for analytics and ad measurement. This setting applies to all Game co., Ltd. sites. Details