The ARM64 MMU back-end allocated address space identifiers (ASIDs) for memory domains with a bare round-robin counter…
Summary
Vulnerability reported (CVE-2026-19574). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
The ARM64 MMU back-end allocated address space identifiers (ASIDs) for memory domains with a bare round-robin counter in arch_mem_domain_init() (arch/arm64/core/mmu.c). VM_ASID_BITS is 8, so only 255 ASIDs exist; once the counter wrapped, arch_mem_domain_init() could hand an ASID to a new domain while a still-live domain held the same one. Domain-private mappings are installed non-global (MT_NG), so the ASID is the only tag separating one domain's cached translations from another's in the TLB.
The context-switch path in z_arm64_swap_ptables() only flushes the TLB when the outgoing and incoming domains carry the same ASID, which does not cover a duplicate reached through a third domain: for domains A and C sharing an ASID and an unrelated domain B, the schedule A -> B -> C never takes the flush branch, so the ASID-tagged entries A populated remain resident while C runs. Under SMP two live domains sharing an ASID can additionally be resident on two CPUs at once, which the architecture does not allow for distinct translation-table sets.
Triggering the wrap requires a CONFIG_USERSPACE application on ARM64 that creates more than 255 memory domains over its lifetime; k_mem_domain_init() and k_mem_domain_deinit() are supervisor-only APIs and are not exposed as syscalls, so an unprivileged thread cannot drive the counter directly. Once two live domains alias, however, a user-mode thread in one domain can read and write memory belonging to the other domain's partitions and thread st…
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-19574 has been found.
Successful exploitation can lead to full system takeover. CVSS score: 7.0/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "CVE-2026-19574" on the vendor's site.
CVE-2026-19574 — CWE-284 / CVSS v3 7.0
Attack vector: local / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-284) has been reported.
Check the vendor advisory for the affected versions.
Severity: High (CVSS 7.0/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで影響コンポーネントを特定する。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。