Categories
CVE-2026-19574 high CVSS 7.0

The ARM64 MMU back-end allocated address space identifiers (ASIDs) for memory domains with a bare round-robin counter…

Summary

Vulnerability reported (CVE-2026-19574). Successful exploitation can lead to full system takeover.

Original description

The description as published by the source.

The ARM64 MMU back-end allocated address space identifiers (ASIDs) for memory domains with a bare round-robin counter in arch_mem_domain_init() (arch/arm64/core/mmu.c). VM_ASID_BITS is 8, so only 255 ASIDs exist; once the counter wrapped, arch_mem_domain_init() could hand an ASID to a new domain while a still-live domain held the same one. Domain-private mappings are installed non-global (MT_NG), so the ASID is the only tag separating one domain's cached translations from another's in the TLB.

The context-switch path in z_arm64_swap_ptables() only flushes the TLB when the outgoing and incoming domains carry the same ASID, which does not cover a duplicate reached through a third domain: for domains A and C sharing an ASID and an unrelated domain B, the schedule A -> B -> C never takes the flush branch, so the ASID-tagged entries A populated remain resident while C runs. Under SMP two live domains sharing an ASID can additionally be resident on two CPUs at once, which the architecture does not allow for distinct translation-table sets.

Triggering the wrap requires a CONFIG_USERSPACE application on ARM64 that creates more than 255 memory domains over its lifetime; k_mem_domain_init() and k_mem_domain_deinit() are supervisor-only APIs and are not exposed as syscalls, so an unprivileged thread cannot drive the counter directly. Once two live domains alias, however, a user-mode thread in one domain can read and write memory belonging to the other domain's partitions and thread st…

Source: NIST National Vulnerability Database NVD

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-19574 has been found.
Successful exploitation can lead to full system takeover. CVSS score: 7.0/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "CVE-2026-19574" on the vendor's site.

CVE-2026-19574 — CWE-284 / CVSS v3 7.0
Attack vector: local / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-284) has been reported.

📍 Affected scope

Check the vendor advisory for the affected versions.

🔥 Severity

Severity: High (CVSS 7.0/10). Successful exploitation can lead to full system takeover.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで影響コンポーネントを特定する。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References

We use cookies for analytics and ad measurement. This setting applies to all Game co., Ltd. sites. Details