Information Disclosure in Atlassian Confluence Data Center (CVE-2026-21579)
Summary
Vulnerability in Atlassian Confluence Data Center (CVE-2026-21579). Confidential information can be exposed externally.
Original description
The description as published by the source.
This High severity Information Disclosure vulnerability was introduced in versions 7.17.0, 7.19.0, 8.5.0, 8.9.0, 9.0.1, 9.1.0, 9.2.0, 10.0.2, 10.1.0, and 10.2.0 of Confluence Data Center.
This Information Disclosure vulnerability, with a CVSS Score of 8.2, allows an unauthenticated attacker to view sensitive information via an Information Disclosure vulnerability.
Atlassian recommends that Confluence Data Center customers upgrade to latest version, if you are unable to do so, upgrade your instance to one of the specified supported fixed versions:
Confluence Data Center 9.2: Upgrade to a release greater than or equal to 9.2.22
Confluence Data Center 10.2: Upgrade to a release greater than or equal to 10.2.14
See the release notes ([https://confluence.atlassian.com/doc/confluence-release-notes-327.html]). You can download the latest version of Confluence Data Center from the download center ([https://www.atlassian.com/software/confluence/download-archives]).
This vulnerability was reported via our Atlassian (Internal) program.
Source: GitHub Security Advisories (Global) NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-21579 has been found in Atlassian Confluence Data Center.
Confidential information can be exposed externally. CVSS score: 7.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Atlassian Confluence Data Center CVE-2026-21579" on the vendor's site.
CVE-2026-21579 (Atlassian Confluence Data Center) — CWE-200 / CVSS v3 7.5
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
Information disclosure (CWE-200) exists in Atlassian Confluence Data Center.
Check the vendor advisory for the affected versions of Atlassian Confluence Data Center.
Severity: High (CVSS 7.5/10). Confidential information can be exposed externally.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Atlassian Confluence Data Center を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- web nvd.nist.gov
- web confluence.atlassian.com
- web jira.atlassian.com