Vulnerability in Golioth Firmware SDK (CVE-2026-23749)
Summary
Vulnerability in Golioth Firmware SDK (CVE-2026-23749). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
Golioth Firmware SDK version 0.19.1 prior to 0.22.0, fixed in commit 0e788217, contain an out-of-bounds read due to improper null termination of a blockwise transfer path. blockwise_transfer_init() accepts a path whose length equals CONFIG_GOLIOTH_COAP_MAX_PATH_LEN and copies it using strncpy() without guaranteeing a trailing NUL byte, leaving ctx->path unterminated. A later strlen() on this buffer (in golioth_coap_client_get_internal()) can read past the end of the allocation, resulting in a crash/denial of service. The input is application-controlled (not network by default).
Source: NIST National Vulnerability Database NVD
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-23749 has been found in Golioth Firmware SDK.
Risk of unauthorized operations or information disclosure. CVSS score: 2.9/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Golioth Firmware SDK CVE-2026-23749" on the vendor's site.
CVE-2026-23749 (Golioth Firmware SDK) — CWE-170 / CVSS v3 2.9
Attack vector: local / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-170) exists in Golioth Firmware SDK.
Check the vendor advisory for the affected versions of Golioth Firmware SDK.
Severity: Low (CVSS 2.9/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Golioth Firmware SDK を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。