Categories
CVE-2026-3611 critical CVSS 10.0

Vulnerability in Honeywell (CVE-2026-3611)

Summary

Vulnerability in Honeywell (CVE-2026-3611). Successful exploitation can lead to full system takeover.

Original description

The description as published by the source.

The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.

Source: NIST National Vulnerability Database NVD

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-3611 has been found in Honeywell.
Successful exploitation can lead to full system takeover. CVSS score: 10.0/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Honeywell CVE-2026-3611" on the vendor's site.

CVE-2026-3611 (Honeywell) — CWE-306 / CVSS v3 10.0
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-306) exists in Honeywell.

📍 Affected scope

Check the vendor advisory for the affected versions of Honeywell.

🔥 Severity

Severity: Critical (CVSS 10.0/10). Successful exploitation can lead to full system takeover.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Run grep -r 'Honeywell' . against your dependency files (package-lock.json, requirements.txt, go.sum) to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    grep -r 'Honeywell' . | grep -v node_modules

    リポジトリと本番環境の依存ファイル (package-lock.json / requirements.txt / go.sum / Gemfile.lock 等) で Honeywell を grep し、稼働しているサービス・バージョンを把握する。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References