Vulnerability in Bosch Sensortec BHI385 SensorAPI (CVE-2026-42805)

Summary

Vulnerability in Bosch Sensortec BHI385 SensorAPI (CVE-2026-42805). Successful exploitation can lead to full system takeover.

Original description

The description as published by the source.

A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI385 SensorAPI (C library) within the debug message parser function bhi385_parse_debug_message (located in bhi385_parse.c).

The function parses FIFO events and extracts an 8-bit message length directly from the attacker-controlled event payload (callback_info->data_ptr[0]) without enforcing bounds checks or clamping the value.

When copying the payload into a fixed-size stack buffer of 17 bytes (uint8_t debug_msg[17]) via memcpy, providing a length byte greater than 16 causes the function to write past the allocated stack boundary.

This memory corruption can be triggered by a malicious or compromised sensor or bus participant, leading to a firmware crash, Denial of Service (DoS), or potentially the execution of arbitrary code via adjacent stack data corruption.

Source: NIST National Vulnerability Database NVD GitHub Advisory

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-42805 has been found in Bosch Sensortec BHI385 SensorAPI.
Successful exploitation can lead to full system takeover. CVSS score: 8.4/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Bosch Sensortec BHI385 SensorAPI CVE-2026-42805" on the vendor's site.

CVE-2026-42805 (Bosch Sensortec BHI385 SensorAPI) — CWE-121 / CVSS v3 8.4
Attack vector: local / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-121) exists in Bosch Sensortec BHI385 SensorAPI.

📍 Affected scope

Check the vendor advisory for the affected versions of Bosch Sensortec BHI385 SensorAPI.

🔥 Severity

Severity: High (CVSS 8.4/10). Successful exploitation can lead to full system takeover.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで Bosch Sensortec BHI385 SensorAPI を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References

We use cookies for analytics and ad measurement. This setting applies to all Game co., Ltd. sites. Details