Categories
CVE-2026-4638

Vulnerability in PRTG Network Monitor (CVE-2026-4638)

Summary

Vulnerability in PRTG Network Monitor (CVE-2026-4638). Risk of unauthorized operations or information disclosure.

Original description

The description as published by the source.

PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter. 

Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

Source: NIST National Vulnerability Database NVD GitHub Advisory

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-4638 has been found in PRTG Network Monitor.
Risk of unauthorized operations or information disclosure.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "PRTG Network Monitor CVE-2026-4638" on the vendor's site.

CVE-2026-4638 (PRTG Network Monitor) — CWE-209
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-209) exists in PRTG Network Monitor.

📍 Affected scope

Check the vendor advisory for the affected versions of PRTG Network Monitor.

🔥 Severity

Severity: ?. Risk of unauthorized operations or information disclosure.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで PRTG Network Monitor を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。