Categories
CVE-2026-48149 high CVSS 8.1

Cross-Site Scripting (XSS) in Budibase (CVE-2026-48149)

Summary

Cross-site scripting in Budibase (CVE-2026-48149). Confidential information can be exposed externally. Mitigation: upgrade to 3.39.0 or later.

Original description

The description as published by the source.

Budibase is an open-source low-code platform. Prior to 3.39.0, the Budibase Text component renders markdown by assigning marked.parse(markdown) straight to innerHTML with no sanitizer (packages/bbui/src/Markdown/MarkdownViewer.svelte:22). Any column a builder binds to a Text component in Markdown mode is a stored-XSS sink writable by every BASIC app user with WRITE on the underlying table. This vulnerability is fixed in 3.39.0.

Source: NIST National Vulnerability Database NVD GitHub Advisory

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-48149 has been found in Budibase.
Confidential information can be exposed externally. CVSS score: 8.1/10.
What to do: upgrade Budibase to 3.39.0 or later.
If unsure, ask your IT team or search "Budibase CVE-2026-48149" on the vendor's site.

CVE-2026-48149 (Budibase) — CWE-79 / CVSS v3 8.1
Attack vector: remote (network-reachable) / no user interaction
Patched: 3.39.0 — apply immediately
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

Cross-site scripting (XSS) (CWE-79) exists in Budibase.

📍 Affected scope

Check the vendor advisory for the affected versions of Budibase.

🔥 Severity

Severity: High (CVSS 8.1/10). Confidential information can be exposed externally.

🔧 How to fix

Update to 3.39.0.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Run grep -r 'Budibase' . against your dependency files (package-lock.json, requirements.txt, go.sum) to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    grep -r 'Budibase' . | grep -v node_modules

    リポジトリと本番環境の依存ファイル (package-lock.json / requirements.txt / go.sum / Gemfile.lock 等) で Budibase を grep し、稼働しているサービス・バージョンを把握する。

  2. 2
    Apply patch patch
    Upgrade Budibase to 3.39.0

    ステージング環境で 3.39.0 に上げて回帰テスト → 本番反映。回帰テストはアプリの主要ハッピーパスを含めること。

  3. 3
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References