Unrestricted File Upload in Siveillance Control Pro (CVE-2026-50093)
Summary
Vulnerability in Siveillance Control Pro (CVE-2026-50093). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
A vulnerability has been identified in Siveillance Control Pro V3.0 (All versions < V3.0.12.2173), Siveillance Control Pro V4.0 (All versions < V4.0.9.2178), Siveillance Control V3.0 (All versions < V3.0.22.2177), Siveillance Control V4.0 (All versions < V4.0.11.2177). A vulnerability in the OIS web module allows an attacker to upload arbitrary files to the server. Successful exploitation of this vulnerability could allow an attacker to gain root access on the host system, potentially leading to a full compromise of the affected OIS environment.
Source: NIST National Vulnerability Database NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-50093 has been found in Siveillance Control Pro.
Successful exploitation can lead to full system takeover. CVSS score: 9.0/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Siveillance Control Pro CVE-2026-50093" on the vendor's site.
CVE-2026-50093 (Siveillance Control Pro) — CWE-434 / CVSS v3 9.0
Attack vector: adjacent-network / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-434) exists in Siveillance Control Pro.
Check the vendor advisory for the affected versions of Siveillance Control Pro.
Severity: Critical (CVSS 9.0/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Siveillance Control Pro を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- web cert-portal.siemens.com
- web nvd.nist.gov
- web github.com