Categories
CVE-2026-5667

Vulnerability in Mitsubishi Electric Room Air Conditioners (CVE-2026-5667)

Summary

Vulnerability in Mitsubishi Electric Room Air Conditioners (CVE-2026-5667). Risk of unauthorized operations or information disclosure.

Original description

The description as published by the source.

Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Room Air Conditioners (for Japan and outside Japan); Wireless LAN Adapters for Room Air Conditioners (for Japan and outside Japan); Wireless LAN Adapters for Packaged Air Conditioners (for Japan and outside Japan); Refrigerators (for Japan); Heat Pump Water Heaters / HEMS-Compatible Adapters / Wireless LAN Adapters (for Japan); Bathroom Dryer / Heater / Ventilation Systems (for Japan); Adapters for Airflow Ventilation Systems, Heat Pump Chilled / Hot Water Systems, and Ventilation / Air-Conditioning System Air Resorts (for Japan); Lossnay Central Ventilation Systems (for Japan); Smart Switches for Ventilation Fans and Lossnay (for Japan); IH Cooking Heaters (for Japan); and Rice Cookers (for Japan) allows an attacker within Wi-Fi radio range of an affected product to access the affected product using a hard-coded SSID and password, thereby obtaining device data such as operation status, room set temperature, and room temperature; changing the air-conditioner or Wi-Fi settings; or causing Wi-Fi communication to enter a denial-of-service (DoS) condition.

Source: JVN (Japan Vulnerability Notes) NVD GitHub Advisory

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-5667 has been found in Mitsubishi Electric Room Air Conditioners.
Risk of unauthorized operations or information disclosure.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Mitsubishi Electric Room Air Conditioners CVE-2026-5667" on the vendor's site.

CVE-2026-5667 (Mitsubishi Electric Room Air Conditioners) — CWE-798
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-798) exists in Mitsubishi Electric Room Air Conditioners.

📍 Affected scope

Check the vendor advisory for the affected versions of Mitsubishi Electric Room Air Conditioners.

🔥 Severity

Severity: ?. Risk of unauthorized operations or information disclosure.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで Mitsubishi Electric Room Air Conditioners を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References

We use cookies for analytics and ad measurement. This setting applies to all Game co., Ltd. sites. Details