After dispatching a decrypt operation to OCF and receiving the result, the wg(4) driver failed to...
Summary
Vulnerability reported (CVE-2026-58085). Data can be tampered with by attackers.
Original description
The description as published by the source.
After dispatching a decrypt operation to OCF and receiving the result, the wg(4) driver failed to check whether the MAC verification step succeeded. The driver thus silently accepted packets with an invalid Poly1305 authentication tag.
A remote attacker who can send UDP packets to a WireGuard endpoint, and who can guess the bounds of the receiver's replay window, can inject forged or modified transport data packets into the tunnel.
A remote attacker who can intercept WireGuard packets bound for a FreeBSD host can modify the ciphertext and authenticated data without detection by the receiver.
Source: NIST National Vulnerability Database NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-58085 has been found.
Data can be tampered with by attackers. CVSS score: 7.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "CVE-2026-58085" on the vendor's site.
CVE-2026-58085 — CWE-347 / CVSS v3 7.5
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-347) has been reported.
Check the vendor advisory for the affected versions.
Severity: High (CVSS 7.5/10). Data can be tampered with by attackers.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで影響コンポーネントを特定する。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。