Categories
CVE-2026-63089 critical CVSS 9.3

Vulnerability in WireGuard Easy (CVE-2026-63089)

Summary

Vulnerability in WireGuard Easy (CVE-2026-63089). Confidential information can be exposed externally.

Original description

The description as published by the source.

WireGuard Easy through 15.3.0, fixed in commit 66b292b, contains a cryptographically weak one-time link token generation vulnerability that allows unauthenticated network attackers to recover WireGuard peer credentials by brute-forcing a keyspace of at most 1000 candidate tokens per client ID, as the token is computed using CRC32 over a random value constrained to 0-999. Attackers can enumerate candidate tokens against the unauthenticated /cnf/:oneTimeLink route, which lacks rate limiting and does not validate token expiration, to obtain a peer's PrivateKey and PresharedKey and impersonate that peer on the VPN network.

Source: NIST National Vulnerability Database NVD GitHub Advisory

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-63089 has been found in WireGuard Easy.
Confidential information can be exposed externally. CVSS score: 9.3/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "WireGuard Easy CVE-2026-63089" on the vendor's site.

CVE-2026-63089 (WireGuard Easy) — CWE-338 / CVSS v3 9.3
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-338) exists in WireGuard Easy.

📍 Affected scope

Check the vendor advisory for the affected versions of WireGuard Easy.

🔥 Severity

Severity: Critical (CVSS 9.3/10). Confidential information can be exposed externally.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで WireGuard Easy を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References