Vulnerability in COVESA Open1722 (CVE-2026-73523)
Summary
Vulnerability in COVESA Open1722 (CVE-2026-73523). Confidential information can be exposed externally.
Original description
The description as published by the source.
COVESA Open1722 through 0.9.2 contains an integer truncation vulnerability in acf-can-listener.c that allows unauthenticated remote attackers to cause the CAN listener to transmit process stack memory onto the CAN bus by sending a rejected UDP datagram with a matching AVTP stream ID. The num_can_msgs variable declared as uint8_t truncates the -1 error return value from avtp_to_can() to 255, causing a write loop to iterate 255 times over a 15-slot stack array and leak approximately 18 KB of adjacent stack memory as roughly 240 CAN frames to any recipient on the CAN bus.
Source: GitHub Security Advisories (Global) NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-73523 has been found in COVESA Open1722.
Confidential information can be exposed externally. CVSS score: 7.5/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "COVESA Open1722 CVE-2026-73523" on the vendor's site.
CVE-2026-73523 (COVESA Open1722) — CWE-197 / CVSS v3 7.5
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-197) exists in COVESA Open1722.
Check the vendor advisory for the affected versions of COVESA Open1722.
Severity: High (CVSS 7.5/10). Confidential information can be exposed externally.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで COVESA Open1722 を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- web nvd.nist.gov
- web disclosure@vulncheck.com
- web disclosure@vulncheck.com
- web github.com